Safe rejection of invalid multibyte MWM command lines
When workspace-session support parses a command line supplied as an in-memory string, it now rejects a line whose first multibyte character is invalid before entering the byte-copy loop. Previously the parser marked its output pointer as unavailable but could still enter that loop after encountering a later valid byte sequence, which could dereference the null sentinel.
The parser continues to report the line as unavailable and preserves the existing handling for valid multibyte input. This only changes malformed input handling; it does not reinterpret valid session commands or configuration syntax.
tests/automated/check-mwm-invalid-multibyte-line.py protects the control-flow
contract: the invalid-initial-sequence guard must enclose the copy loop.