MWM workspace transient-tree traversal
The standalone MWM workspace protocol may inspect every transient client when
it answers WSM_GET_STATE, restores visibility after a workspace-manager
change, or resolves a registered client window. A valid transient hierarchy
can be much deeper than a process call stack, so recursive traversal could
terminate MWM while answering an otherwise ordinary workspace request.
WmWorkspace.c now uses one explicit, heap-backed depth-first frame stack.
It retains the prior parent-before-child and sibling order, stops safely if
its stack cannot grow, and bounds WSM_GET_STATE to the protocol's CARD16
entry limit. If a reply snapshot cannot be completed, already-owned
per-window data is released and an empty, valid reply is returned rather than
publishing a partial ownership graph.
The focused source regression is:
python3 tests/automated/check-mwm-workspace-tree-walk.py
CK Core Motif